XS Cooler - Xinsheng Heat Exchanger
Straßenfertiger Kühlsystem
Baumaschinen

Straßenfertiger Kühlsystem

Die Herausforderung

Kompaktes Kühlsystem für zuverlässigen Betrieb in Hochtemperatur-Asphaltumgebungen erforderlich

Unsere Lösung

Maßgeschneidertes Kühlmodul speziell für Hochtemperaturumgebungen mit Wärmeschutz und optimiertem Luftstrommanagement

Wichtige Ergebnisse

  • Zuverlässiger Betrieb bei 80°C Asphalttemperatur
  • 25% verbesserte Kühleffizienz
  • 20% kompakteres System

Project Background

An international road construction equipment OEM required a cooling system for their new generation asphalt paver. The unique operating environment—proximity to hot asphalt and screed heating elements—demanded specialized thermal protection beyond standard construction equipment solutions.

Application Challenges

Extreme Thermal Environment

  • Freshly laid asphalt temperatures exceed 150°C
  • Screed heating elements radiate additional heat to engine compartment
  • Ambient temperatures effectively +20-30°C above actual air temperature

Contamination Exposure

  • Asphalt vapors coat heat transfer surfaces
  • Fine aggregate dust clogs fin passages
  • Regular cleaning required during paving operations

Continuous Duty

  • Paving operations run 8-12 hours continuously
  • Heat soak during material loading pauses
  • No opportunity for cool-down during production

Solution Development

Thermal Protection

  • Heat shields between cooling package and screed area
  • Increased core sizing to compensate for elevated ambient
  • Dedicated fan circuit for consistent airflow independent of engine speed

Contamination Resistance

  • Wide fin spacing (3.5 FPI) for easy vapor and dust cleaning
  • Smooth fin surface finish to reduce tar adhesion
  • Quick-release mounting for regular core cleaning access

Material Selection

  • High-temperature resistant tank materials
  • Reinforced fin construction for pressure washing durability
  • Corrosion protection for aggressive environment

Validation Program

Testing included:

  • Extended thermal testing at +60°C ambient
  • Accelerated contamination/cleaning cycle testing
  • Field validation on active paving projects

Production Implementation

Volume production commenced Q2 2024. The solution is now specified on multiple paver platforms from this OEM.


Note: Customer identity and proprietary specifications are confidential. Contact us to discuss your road machinery cooling requirements.

Branche

Construction Machinery

Ähnliche Herausforderung?

Unsere Ingenieure helfen Ihnen gerne bei Ihren Wärmemanagement-Problemen.

Kontakt aufnehmen